Search results for "Fully automated"

showing 10 items of 12 documents

Performance evaluation of a newly developed molecular assay for the accurate diagnosis of gastroenteritis associated with norovirus of genogroup II

2018

The performance of a newly proposed fully automated cassette-based sample-to-results solution for norovirus (NoV) detection, InGenius Norovirus ELITe MGB®, was evaluated. A total of 120 selected archival stool samples from children hospitalized for acute gastroenteritis were used to compare the results to a reference real-time RT-PCR. The InGenius NoV assay showed optimal diagnostic accuracy (sensitivity, 100%; specificity, 95.7%) and was able to correctly detect the entire wide panel of epidemiologically relevant genotypes tested. These preliminary results suggest that the InGenius NoV assay can be recommended as a valuable method for accurate diagnosis of NoV GII infection in epidemic and…

0301 basic medicineMalemedicine.medical_specialtySettore MED/07 - Microbiologia E Microbiologia ClinicaAdolescentGenotype030106 microbiologyDiagnostic accuracyBiologymedicine.disease_causeReal-Time Polymerase Chain ReactionSensitivity and SpecificityFeces03 medical and health sciencesMedical microbiologyVirologyGenotypemedicineHumansChildCaliciviridae InfectionsNoroviruCaliciviridae InfectionGastroenteritiReverse Transcriptase Polymerase Chain ReactionNorovirusInfantGeneral MedicineAcute gastroenteritisbacterial infections and mycosesVirologyGastroenteritis030104 developmental biologyCaliciviridae InfectionsFully automatedChild PreschoolNorovirusFeceFemaleHuman
researchProduct

Diagnostic accuracy of a fully automated multiplex celiac disease antibody panel for serum and plasma.

2019

Abstract Background An automated multiplex platform using capillary blood can promote greater throughput and more comprehensive studies in celiac disease (CD). Diagnostic accuracy should be improved using likelihood ratios for the post-test probability of ruling-in disease. Methods The Ig_plex™ Celiac Disease Panel on the sqidlite™ automated platform measured IgA and IgG antibodies to tTG and DGP in n = 224 CD serum or plasma samples. Diagnostic accuracy metrics were applied to the combined multiplex test results for several CD populations and compared to conventional single antibody ELISA tests. Results With multiple positive antibody results, the post-test probability for ruling-in untrea…

AdultMalemedicine.medical_specialtyAdolescentClinical BiochemistryDiagnostic accuracyEnzyme-Linked Immunosorbent AssayDiseaseGastroenterology03 medical and health sciencesAutomationYoung Adult0302 clinical medicineCapillary PlasmaPredictive Value of TestsInternal medicineBiopsymedicineHumansMultiplex030212 general & internal medicineChildAutoantibodiesbiologymedicine.diagnostic_testbusiness.industryBiochemistry (medical)General MedicineMiddle AgedResponse to treatmentCeliac DiseaseFully automatedChild Preschoolbiology.protein030211 gastroenterology & hepatologyFemaleAntibodybusinessBlood Chemical AnalysisClinical chemistry and laboratory medicine
researchProduct

A fully automated system for the evaluation of masseter silent periods.

1997

Exteroceptive suppression of masseter muscle activity, 'masseter inhibitory reflex', comprises one or 2 silent periods (SP1 and SP2) interrupting the voluntary activation. The main problem when evaluating exteroceptive suppression is the lack of an objective and precise measure for the onset and end of the silent period which so far has not been overcome by various automated systems. We describe a new fully automated system for determining the onset and end of the masseter silent period. The decision approach is essentially based upon deterministic properties of median filters which are used to partition the local variances of the EMG traces into constant segments and edges between them. Th…

Adultmedicine.medical_specialtyAnalysis of Variancemedicine.diagnostic_testAdolescentComputer scienceElectromyographyMasseter MuscleGeneral NeuroscienceComputer aidElectromyographyAudiologyMasseter muscleAutomationFully automatedReference ValuesHealthy volunteersmedicineReflexHumansSilent periodNeurology (clinical)Decision processElectroencephalography and clinical neurophysiology
researchProduct

FRIPON: a worldwide network to track incoming meteoroids

2020

Context. Until recently, camera networks designed for monitoring fireballs worldwide were not fully automated, implying that in case of a meteorite fall, the recovery campaign was rarely immediate. This was an important limiting factor as the most fragile - hence precious - meteorites must be recovered rapidly to avoid their alteration. Aims. The Fireball Recovery and InterPlanetary Observation Network (FRIPON) scientific project was designed to overcome this limitation. This network comprises a fully automated camera and radio network deployed over a significant fraction of western Europe and a small fraction of Canada. As of today, it consists of 150 cameras and 25 European radio receiver…

DYNAMICS[INFO.INFO-AR]Computer Science [cs]/Hardware Architecture [cs.AR]MeteorsComputer scienceRadio receiver[INFO.INFO-DM]Computer Science [cs]/Discrete Mathematics [cs.DM]Surveys010502 geochemistry & geophysicsTrack (rail transport)01 natural sciencesMeteorites meteors meteoroidslaw.inventionPlanets and planetary system[INFO.INFO-TS]Computer Science [cs]/Signal and Image ProcessingMethods: observationallaw[INFO.INFO-RB]Computer Science [cs]/Robotics [cs.RO]meteoroids010303 astronomy & astrophysicsComputingMilieux_MISCELLANEOUSObservational methodsEarth and Planetary Astrophysics (astro-ph.EP)meteoroids -surveys -methods: observational -interplanetary medium[SDU.ASTR]Sciences of the Universe [physics]/Astrophysics [astro-ph]ORIGIN[INFO.INFO-AO]Computer Science [cs]/Computer Arithmeticmeteorites meteors meteoroids – surveys – methods: observational – interplanetary mediumMeteoroidsRECOVERYORBITMeteoriteFully automatedInterplanetary medium; Meteorites meteors meteoroids; Methods: observational; Surveys[INFO.INFO-TI]Computer Science [cs]/Image Processing [eess.IV][INFO.INFO-DC]Computer Science [cs]/Distributed Parallel and Cluster Computing [cs.DC]Astrophysics - Instrumentation and Methods for Astrophysics[SPI.SIGNAL]Engineering Sciences [physics]/Signal and Image processingFLUXReal-time computingfripon[INFO.INFO-DS]Computer Science [cs]/Data Structures and Algorithms [cs.DS]FOS: Physical sciencesContext (language use)CAMERA[INFO.INFO-SE]Computer Science [cs]/Software Engineering [cs.SE][SPI.AUTO]Engineering Sciences [physics]/Automatic[SDU.STU.PL]Sciences of the Universe [physics]/Earth Sciences/Planetology0103 physical sciencesFIREBALL NETWORKobservational [Methods]meteorsInstrumentation and Methods for Astrophysics (astro-ph.IM)0105 earth and related environmental sciencesMeteoroidINNISFREE METEORITE[INFO.INFO-CV]Computer Science [cs]/Computer Vision and Pattern Recognition [cs.CV]Astronomy and AstrophysicsMETEORITE FALLMeteorites meteors meteoroidCamera networkSpace and Planetary Science[SDU]Sciences of the Universe [physics]Interplanetary spaceflightmeteroids trackingmeteoroids - surveys - methods: observationalSYSTEMInterplanetary mediumAstrophysics - Earth and Planetary AstrophysicsMeteorites
researchProduct

Photochemical-chemiliminometric determination of aldicarb in a fully automated multicommutation based flow-assembly

2004

[EN] A sensitive and fully automated method for determination of aldicarb in technical formulations (Temik) and mineral waters is proposed. The automation of the flow-assembly is based on the multicommutation approach, which uses a set of solenoid valves acting as independent switchers. The operating cycle for obtaining a typical analytical transient signal can be easily programmed by means of a home-made software running in the Windows environment. The manifold is provided with a photoreactor consisting of a 150 cm long x 0.8 mm i.d. piece of PTFE tubing coiled around a 20 W low-pressure mercury lamp. The determination of aldicarb is performed on the basis of the iron(III) catalytic minera…

Detection limitChromatographyChemiluminescenceAldicarbAnalytical chemistryBiochemistryAnalytical Chemistrylaw.inventionMercury-vapor lampchemistry.chemical_compoundPotassium permanganatechemistryFully automatedlawMulticommutationTandem-flowPhotodegradationQUIMICA ANALITICAEnvironmental ChemistryPhotodegradationSpectroscopyTransient signalAldicarbChemiluminescence
researchProduct

Improved automated synthesis of [18F]fluoroethylcholine as a radiotracer for cancer imaging.

2007

[(18)F]Fluoroethylcholine has been recently introduced as a promising (18)F-labelled analogue of [(11)C]choline which had been previously described as a tracer for metabolic cancer imaging with positron emission tomography (PET). Due to the practical advantages of using the longer-lived radioisotope (18)F (t(1/2)=110 min), offering the opportunity of a more widespread clinical application, we established a reliable, fully automated synthesis for its production using a modified, commercially available module. [(18)F]Fluoroethylcholine was prepared from N,N-dimethylaminoethanol by iodide catalyzed alkylation with 1-[(18)F]fluoro-2-tosylethane as alkylating agent, resulting in a total radioche…

Fluorine RadioisotopesClinical BiochemistryIodidePharmaceutical ScienceCancer imagingAlkylationBiochemistryChemical synthesisSensitivity and SpecificityCholineNeoplasmsDrug DiscoverymedicineMolecular BiologyChromatography High Pressure LiquidFluoroethylcholinechemistry.chemical_classificationmedicine.diagnostic_test18F-FluoroethylcholineMolecular StructureChemistryOrganic ChemistryRadiochemistryBiochemistryFully automatedPositron emission tomographyMolecular MedicineBioorganicmedicinal chemistry
researchProduct

Application of Nanogen microarray technology for forensic SNP analysis

2006

Abstract The NanoChip® Molecular Biology Workstation using electronic microarrays is an approach for rapid and high throughput analysis of SNPs. This instrument is fully automated and uses a microchip for electronic addressing of capture probes to specific array sites followed by electronic hybridisation of the single stranded PCR products, and passive hybridisation of fluorescently labelled reporter probes. Discrimination is achieved by applying thermal stringency to denature the mismatched reporters. 48 SNP assays have been designed using the ‘capture down’ assay which applies a thermal ‘touch down’ strategy to obtain the best reporter probe discrimination.

GeneticsFully automatedPcr cloningGene chip analysisGeneral MedicineComputational biologyBiologyDNA microarraySNP arrayHigh throughput analysisInternational Congress Series
researchProduct

A Multicentre Pilot Study of a Two-Tier Newborn Sickle Cell Disease Screening Procedure with a First Tier Based on a Fully Automated MALDI-TOF MS Pla…

2019

The reference methods used for sickle cell disease (SCD) screening usually include two analytical steps: a first tier for differentiating haemoglobin S (HbS) heterozygotes, HbS homozygotes and β-thalassemia from other samples, and a confirmatory second tier. Here, we evaluated a first-tier approach based on a fully automated matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) platform with automated sample processing, a laboratory information management system and NeoSickle® software for automatic data interpretation. A total of 6701 samples (with high proportions of phenotypes homozygous (FS) or heterozygous (FAS) for the inherited genes for sickle h…

MALDI-TOFPediatricsmedicine.medical_specialtythalassemia[SDV]Life Sciences [q-bio]Sample (statistics)01 natural sciencesArticle03 medical and health sciencesImmunology and Microbiology (miscellaneous)preventionmedicineDisease Screening Procedure030304 developmental biologymass spectrometry0303 health sciencesNewborn screeningbusiness.industryMALDI-TOF; sickle cell disease; newborn screening; mass spectrometry; thalassemia; preventionnewborn screening010401 analytical chemistrylcsh:RJ1-570Obstetrics and GynecologyData interpretationlcsh:Pediatrics0104 chemical sciencesMatrix-assisted laser desorption/ionizationFully automatedSickle haemoglobinPediatrics Perinatology and Child Healthsickle cell diseaseSample collectionbusinessInternational Journal of Neonatal Screening
researchProduct

Workflow-centred open-source fully automated lung volumetry in chest CT

2019

Aim To develop a robust open-source method for fully automated extraction of total lung capacity (TLC) from computed tomography (CT) images and to demonstrate its integration into the clinical workflow. Materials and methods Using only open-source software, an algorithm was developed based on a region-growing method that does not require manual interaction. Lung volumes calculated from reconstructions with different kernels (TLCCT) were assessed. To validate the algorithm calculations, the results were correlated to TLC measured by pulmonary function testing (TLCPFT) in a subgroup of patients for which this information was available within 3 days of the CT examination. Results A total of 28…

MaleChest ct030218 nuclear medicine & medical imagingPulmonary function testing03 medical and health sciencesImaging Three-Dimensional0302 clinical medicineHumansMedicineRadiology Nuclear Medicine and imagingSegmentationLung volumesRetrospective Studiesbusiness.industryGeneral MedicineMiddle Agedrespiratory systemRespiratory Function Testsrespiratory tract diseasesWorkflowOpen sourceFully automated030220 oncology & carcinogenesisLung volumetryRadiographic Image Interpretation Computer-AssistedFemaleRadiography ThoracicLung Volume MeasurementsTomography X-Ray ComputedNuclear medicinebusinessAlgorithmsSoftwareClinical Radiology
researchProduct

A vision-based fully automated approach to robust image cropping detection

2020

Abstract The definition of valid and robust methodologies for assessing the authenticity of digital information is nowadays critical to contrast social manipulation through the media. A key research topic in multimedia forensics is the development of methods for detecting tampered content in large image collections without any human intervention. This paper introduces AMARCORD (Automatic Manhattan-scene AsymmetRically CrOpped imageRy Detector), a fully automated detector for exposing evidences of asymmetrical image cropping on Manhattan-World scenes. The proposed solution estimates and exploits the camera principal point, i.e., a physical feature extracted directly from the image content th…

Robust computer visionExploitComputer scienceComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONRobust statisticsImage processing02 engineering and technologyCropping detectionMultimedia forensicRobustness (computer science)0202 electrical engineering electronic engineering information engineeringMultimedia Forensics Robust Computer Vision Cropping Detection Image Content AnalysisComputer visionElectrical and Electronic EngineeringSettore ING-INF/05 - Sistemi Di Elaborazione Delle InformazioniSettore INF/01 - InformaticaVision basedbusiness.industryDetectorImage content analysi020206 networking & telecommunicationsFully automatedSignal Processing020201 artificial intelligence & image processingComputer Vision and Pattern RecognitionArtificial intelligencebusinessCroppingSoftwareSignal Processing: Image Communication
researchProduct